HOME NEWS COMPANY NEWS What should we pay attention to before installing a high-efficiency air outlet?

COMPANY NEWS

What should we pay attention to before installing a high-efficiency air outlet?

There are many precautions before the installation of the high-efficiency air outlet. The installation details of the high-efficiency air outlet are directly related to the cleanliness of the clean room (clean room), so every installation detail needs to be paid attention to. Here are some caveats:

  1. Before installation, the size and efficiency requirements of the high-efficiency air outlet must meet the clean room site design requirements and customer application standards.
  2. The seam between the flanging of the air outlet and the ceiling panel that needs to be installed with high-efficiency air outlets in the clean room needs to be treated with gaskets, and the cracks must be treated strictly. Remember that the high-efficiency air outlet is damaged or the coating is damaged and cannot be installed. The installation of the air outlet and the air duct must be strictly connected, and the open end is reinforced with plastic film and tape for airtight treatment.
  3. Before installing the high-efficiency air outlet, it is necessary to clean the product and clean the clean room in an all-round way. For example, if there is dust in the purification air-conditioning system, it should be cleaned and removed, and the cleaning requirements must be met. The interlayer or ceiling also needs to be cleaned. , The purification air-conditioning system must be run continuously for more than 12 hours and be cleaned again.
  4. The safe transportation of the high-efficiency air outlet should be placed in strict accordance with the manufacturer's logo instructions. During transportation, it should be handled with care and avoid severe vibration and collision.
  5. Before installing the high-efficiency air outlet, it is necessary to inspect the appearance of the air outlet packaging on site, including whether the filter paper, sealant and frame are damaged; whether the side length, diagonal and thickness dimensions meet the requirements; whether the frame has burrs and rust spots, etc.
  6. For efficient air supply leak detection, the installation should be reasonably adjusted according to the resistance of each air supply. For unidirectional flow, between the filters on the same air outlet or on the air supply surface, the rated resistance of each unit and the The average resistance difference should be less than 5% in order to meet the filtering requirements.